Transimpedance Amplifiers

Current-to-Voltage Amplifier for use with Photodiode-Based Detectors. Transimpedance Amplifiers, Standalone Devices with Data Acquisition as well as Display Function (Optometer). Log/Lin Switching Amplifiers, etc.

We offer specially for radiometry and photometry designed Current-to-Voltage Amplifier for use with Photodiode-Based Detectors. In other words, our transimpedance amplifiers are optimized for photodiodes.

In our product selection we offer transimpedance amplifiers as standalone devices with data acquisition, display and digital interface which we call Optometers. The listed transimpedance amplifiers differ in number of channels, linear or logarithmic amplifiers, amplification ranges, response time, noise level and maximum current allowed.

We are happy to support you to find the best fitting transimpedance amplifier system for your needs.

Overview of Optometer/Current Amplifiers/Transimpedance Amplifiers

Model Image Detector Inputs N.E.I. Noise equivalent input / integration time Max signal input Gain ranges Slew rate (10% to 90%) Remark
P-21 P-21 1 0.1 pA / 100ms 0.005 pA / 5 s (*1) 2 mA 8 normal mode: 2 ms - 10 ms fast mode: 3 µs - 10 ms Highest quality portable optometer with color touchscreen, analog output and trigger. Very large dynamic range. Lowest input offset for smallest measurement signals. Many measuring functions.
X1-RM X1-RM 1 / 4 chanel multiplexed 0.1 pA / 500 ms 200 µA 7 3 ms - 30 ms Optometer module for installation in 19" systems. I / O, USB and RS485 interfaces.
PLL-1701 PLL-1701 SMA / 1 t.b.c. 1mA 9 lin & 1 log 16 µs or 500 µs Fibre and current input, Lin. or Log current amplifier
PFL-200 PFL-200 1 (BNC) 0.1 pA / 5 µs sampling time min at min. measurement time 100 µs 20 µA 9 3dB cut-off: Range 0 to 5 = 10 kHz, Range 6 to 8 = 200Hz Fast amplifier for flicker measurements of Pst, SVM and other metrics or measurements which need fast sampling (up to 200 kHz).
P-9202-4 P-9202-4 1 10 mV pk-pk 5 mA 8 1 µs - 3 µs High quality analogue amplifier with current-voltage conversion
P-9202-5 P-9202-5 1 4 mV pk-pk 5 mA 8 5 µs - 20 ms High quality analogue amplifier with current-voltage conversion
P-9202-6 P-9202-6 1 0.5 mV eff 5 mA 1 25 ms - 2.5 s High quality analogue amplifier with current-voltage conversion
X1-1 X1 1 / 4 chanels multiplexed 0.1 pA / 500 ms 200 µA 7 3 ms - 30 ms Best selling optometer for general applications. X1-Z03 option to connect up to four detectors.
P-9710-1 P-9710 1 0.1 pA / 100ms 0.005 pA / 5 s (*1) 2 mA 8 2 ms - 10 ms High quality portable optometer. Very large dynamic range. Lowest input offset for smallest measurement signals. Many measuring functions.
P-9710-2 P-9710 1 0.1 pA / 100ms 0.005 pA / 5 s (*1) 2 mA 88 20 ms Identical to the P-9710-1 but with 20 ms time constant in all amplifier gain ranges for measuring the pulse energy according to the streched-pulse method.
P-9710-4 P-9710 1 0.1 pA / 100ms 0.005 pA / 5 s (*1) 2 mA 8 20 ms Identical to the P-9710-2 but with additional trigger input for synchronizing the measurement of pulse energy.
P-2000-1 P-2000 2 / multiplexed 0.1 pA / 100ms 0.005 pA / 5 s (*1) 2 mA 8 2 ms - 10 ms High quality 2-channel optometer. Very large dynamic range. Lowest input offset for smallest measurement signals. Many measuring functions.
P-2000-2 P-2000 2 / multiplexed 0.1 pA / 100ms 0.005 pA / 5 s (*1) 2 mA 8 20 ms Same as P-2000 but with 20 ms time constant in all amplifier gain ranges to measure the pulse energy according to the stretched-pulse method.
P-9801-V01 P-9801 8 0.1 pA / 100 ms 2 mA 8 2 ms - 10 ms High-quality 8-channel optometer with 8 separate signal amplifiers. Very large dynamic range. Lowest input offset for smallest measurement signals. Many measuring functions.
P-9801-V02 P-9801 8 0.1 pA / 100 ms 2 mA 8 20 ms Same as P-9801-V01 but with 20 ms time constant in all amplifier gain ranges for measuring the pulse energy according to the strectched-pulse method.
P-9801-V03 P-9801 8 0.1 pA / 100 µs 2 mA 8 1 ms to 10 ms Identical to the P-9801-V01 but with short time constants in all amplifier gain ranges for data logger applications.
P-9802 P-9802 up to 2 x 18 / multiplexed 0.1 pA / 100 µs 200 µA 7 30 ms Individually configurable optometer with up to 36 separate signal inputs.
TR-9600-1 TR-9600 1 60 pA / 1 µs 2 mA 10 1 µs to 30 µs Fast data logger optometer with 1 μs time constant. Transient recorder with 12-bit ADC adjustable from 10 M samples/s to 1 k sample/s sampling rate. 4M bytes of memory.
TR-9600-2 TR-9600 1 20 nA / 100 ns 600 µA 4 100 ns Fast data logger optometer with 100 ns time constant. Transient recorder with 12-bit ADC adjustable from 10 M samples / s - 1 k sample / s sampling rate. 4 M bytes of memory.

(*1)Offset measurement before each measurement recommended